ucs_vsans - Configures VSANs on Cisco UCS Manager

New in version 2.5.

Synopsis

Requirements

The below requirements are needed on the host that executes this module.

  • ucsmsdk

Parameters

Parameter Choices/Defaults Comments
fabric
    Choices:
  • common
  • A
  • B
The fabric configuration of the VSAN. This can be one of the following:
common - The VSAN maps to the same VSAN ID in all available fabrics.
A - The VSAN maps to the a VSAN ID that exists only in fabric A.
B - The VSAN maps to the a VSAN ID that exists only in fabric B.
fc_zoning
    Choices:
  • disabled
  • enabled
Fibre Channel zoning configuration for the Cisco UCS domain.
Fibre Channel zoning can be set to one of the following values:
disabled — The upstream switch handles Fibre Channel zoning, or Fibre Channel zoning is not implemented for the Cisco UCS domain.
enabled — Cisco UCS Manager configures and controls Fibre Channel zoning for the Cisco UCS domain.
If you enable Fibre Channel zoning, do not configure the upstream switch with any VSANs that are being used for Fibre Channel zoning.
hostname
required
IP address or hostname of Cisco UCS Manager.
name
required
The name assigned to the VSAN.
This name can be between 1 and 32 alphanumeric characters.
You cannot use spaces or any special characters other than - (hyphen), "_" (underscore), : (colon), and . (period).
You cannot change this name after the VSAN is created.
password
required
Password for Cisco UCS Manager authentication.
port
Port number to be used during connection (by default uses 443 for https and 80 for http connection).
proxy
If use_proxy is no, specfies proxy to be used for connection. e.g. 'http://proxy.xy.z:8080'
state
    Choices:
  • present
  • absent
If present, will verify VSANs are present and will create if needed.
If absent, will verify VSANs are absent and will delete if needed.
use_proxy
    Choices:
  • no
  • yes
If no, will not use the proxy as defined by system environment variable.
use_ssl
    Choices:
  • no
  • yes
If no, an HTTP connection will be used instead of the default HTTPS connection.
username Default:
admin
Username for Cisco UCS Manager authentication.
vlan_id
required
The unique string identifier assigned to the VLAN used for Fibre Channel connections.
Note that Cisco UCS Manager uses VLAN '4048'. See the UCS Manager configuration guide if you want to assign '4048' to a VLAN.
Optional if state is absent.
vsan_id
required
The unique identifier assigned to the VSAN.
The ID can be a string between '1' and '4078', or between '4080' and '4093'. '4079' is a reserved VSAN ID.
In addition, if you plan to use FC end-host mode, the range between '3840' to '4079' is also a reserved VSAN ID range.
Optional if state is absent.

Examples

- name: Configure VSAN
  ucs_vsans:
    hostname: 172.16.143.150
    username: admin
    password: password
    name: vsan110
    vsan_id: '110'
    vlan_id: '110'

- name: Remove VSAN
  ucs_vsans:
    hostname: 172.16.143.150
    username: admin
    password: password
    name: vsan110

Status

This module is flagged as preview which means that it is not guaranteed to have a backwards compatible interface.

Author

  • David Soper (@dsoper2)
  • CiscoUcs (@CiscoUcs)

Hint

If you notice any issues in this documentation you can edit this document to improve it.

© 2012–2018 Michael DeHaan
© 2018–2019 Red Hat, Inc.
Licensed under the GNU General Public License version 3.