ce_mtu - Manages MTU settings on HUAWEI CloudEngine switches.
New in version 2.4.
Synopsis
- Manages MTU settings on HUAWEI CloudEngine switches.
Parameters
Parameter | Choices/Defaults | Comments |
---|---|---|
interface | Default: None | Full name of interface, i.e. 40GE1/0/22. |
jumbo_max | Default: None | Maximum frame size. The default value is 9216. The value is an integer and expressed in bytes. The value range is 1536 to 12224 for the CE12800 and 1536 to 12288 for ToR switches. |
jumbo_min | Default: None | Non-jumbo frame size threshod. The default value is 1518. The value is an integer that ranges from 1518 to jumbo_max, in bytes. |
mtu | Default: None | MTU for a specific interface. The value is an integer ranging from 46 to 9600, in bytes. |
state |
| Specify desired state of the resource. |
Notes
Note
- Either
sysmtu
param is required orinterface
ANDmtu
params are req’d. -
state=absent
unconfigures a given MTU if that value is currently present.
Examples
- name: Mtu test hosts: cloudengine connection: local gather_facts: no vars: cli: host: "{{ inventory_hostname }}" port: "{{ ansible_ssh_port }}" username: "{{ username }}" password: "{{ password }}" transport: cli tasks: - name: "Config jumboframe on 40GE1/0/22" ce_mtu: interface: 40GE1/0/22 jumbo_max: 9000 jumbo_min: 8000 provider: "{{ cli }}" - name: "Config mtu on 40GE1/0/22 (routed interface)" ce_mtu: interface: 40GE1/0/22 mtu: 1600 provider: "{{ cli }}" - name: "Config mtu on 40GE1/0/23 (switched interface)" ce_mtu: interface: 40GE1/0/22 mtu: 9216 provider: "{{ cli }}" - name: "Config mtu and jumboframe on 40GE1/0/22 (routed interface)" ce_mtu: interface: 40GE1/0/22 mtu: 1601 jumbo_max: 9001 jumbo_min: 8001 provider: "{{ cli }}" - name: "Unconfigure mtu and jumboframe on a given interface" ce_mtu: state: absent interface: 40GE1/0/22 provider: "{{ cli }}"
Return Values
Common return values are documented here, the following are the fields unique to this module:
Key | Returned | Description |
---|---|---|
changed boolean | always | check to see if a change was made on the device Sample: True |
end_state dict | always | k/v pairs of mtu/sysmtu values after module execution Sample: {'jumbo_max': '9000', 'jumbo_min': '8000', 'mtu': '1700'} |
existing dict | always | k/v pairs of existing mtu/sysmtu on the interface/system Sample: {'jumbo_max': '9216', 'jumbo_min': '1518', 'mtu': '1600'} |
proposed dict | always | k/v pairs of parameters passed into module Sample: {'jumbo_max': '9000', 'jumbo_min': '8000', 'mtu': '1700'} |
updates list | always | command sent to the device Sample: ['interface 40GE1/0/23', 'mtu 1700', 'jumboframe enable 9000 8000'] |
Status
This module is flagged as preview which means that it is not guaranteed to have a backwards compatible interface.