pn_vlag - CLI command to create/delete/modify vlag.

New in version 2.2.

Synopsis

  • Execute vlag-create/vlag-delete/vlag-modify command.
  • A virtual link aggregation group (VLAG) allows links that are physically connected to two different Pluribus Networks devices to appear as a single trunk to a third device. The third device can be a switch, server, or any Ethernet device. A VLAG can provide Layer 2 multipathing, which allows you to create redundancy by increasing bandwidth, enabling multiple parallel paths between nodes and loadbalancing traffic where alternative paths exist.

Parameters

Parameter Choices/Defaults Comments
pn_clipassword
Provide login password if user is not root.
pn_cliswitch
Target switch(es) to run this command on.
pn_cliusername
Provide login username if user is not root.
pn_failover_action
    Choices:
  • move
  • ignore
Specify the failover action as move or ignore.
pn_lacp_fallback
    Choices:
  • bundle
  • individual
Specify the LACP fallback mode as bundles or individual.
pn_lacp_fallback_timeout
Specify the LACP fallback timeout in seconds. The range is between 30 and 60 seconds with a default value of 50 seconds.
pn_lacp_mode
    Choices:
  • off
  • passive
  • active
Specify the LACP mode.
pn_lacp_timeout
    Choices:
  • slow
  • fast
Specify the LACP timeout as slow(30 seconds) or fast(4 seconds).
pn_mode
    Choices:
  • active-active
  • active-standby
Specify the mode for the VLAG. Active-standby indicates one side is active and the other side is in standby mode. Active-active indicates that both sides of the vlag are up by default.
pn_name
required
The pn_name takes a valid name for vlag configuration.
pn_peer_port
Specify the peer VLAG port.
Required for vlag-create.
pn_peer_switch
Specify the fabric-name of the peer switch.
pn_port
Specify the local VLAG port.
Required for vlag-create.
state
required
    Choices:
  • present
  • absent
  • update
State the action to perform. Use 'present' to create vlag, 'absent' to delete vlag and 'update' to modify vlag.

Examples

- name: create a VLAG
  pn_vlag:
    state: 'present'
    pn_name: spine-to-leaf
    pn_port: 'spine01-to-leaf'
    pn_peer_port: 'spine02-to-leaf'
    pn_peer_switch: spine02
    pn_mode: 'active-active'

- name: delete VLAGs
  pn_vlag:
    state: 'absent'
    pn_name: spine-to-leaf

Return Values

Common return values are documented here, the following are the fields unique to this module:

Key Returned Description
changed
bool
always
Indicates whether the CLI caused changes on the target.

command
str
always
The CLI command run on the target node(s).

stderr
list
on error
The set of error responses from the vlag command.

stdout
list
always
The set of responses from the vlag command.



Status

This module is flagged as preview which means that it is not guaranteed to have a backwards compatible interface.

Author

  • Pluribus Networks (@amitsi)

Hint

If you notice any issues in this documentation you can edit this document to improve it.

© 2012–2018 Michael DeHaan
© 2018–2019 Red Hat, Inc.
Licensed under the GNU General Public License version 3.
https://docs.ansible.com/ansible/2.5/modules/pn_vlag_module.html