ce_ospf_vrf - Manages configuration of an OSPF VPN instance on HUAWEI CloudEngine switches.

New in version 2.4.

Synopsis

  • Manages configuration of an OSPF VPN instance on HUAWEI CloudEngine switches.

Parameters

Parameter Choices/Defaults Comments
bandwidth Default:
None
Specifies the reference bandwidth used to assign ospf cost. Valid values are an integer, in Mbps, 1 - 2147483648, the default value is 100.
description Default:
None
Specifies the description information of ospf process.
lsaaholdinterval Default:
None
Specifies the hold interval of arrive LSA when use the intelligent timer. Valid value is an integer, in millisecond, from 0 to 10000, the default value is 500.
lsaainterval Default:
None
Specifies the interval of arrive LSA when use the general timer. Valid value is an integer, in millisecond, from 0 to 10000.
lsaalflag Default:
no
Specifies the mode of timer to calculate interval of arrive LSA. If set the parameter but not specifies value, the default will be used. If true use general timer. If false use intelligent timer.
lsaamaxinterval Default:
None
Specifies the max interval of arrive LSA when use the intelligent timer. Valid value is an integer, in millisecond, from 0 to 10000, the default value is 1000.
lsaastartinterval Default:
None
Specifies the start interval of arrive LSA when use the intelligent timer. Valid value is an integer, in millisecond, from 0 to 10000, the default value is 500.
lsaoholdinterval Default:
None
Specifies the hold interval of originate LSA . Valid value is an integer, in millisecond, from 0 to 5000, the default value is 1000.
lsaointerval Default:
None
Specifies the interval of originate LSA . Valid value is an integer, in second, from 0 to 10, the default value is 5.
lsaointervalflag Default:
no
Specifies whether cancel the interval of LSA originate or not. If set the parameter but noe specifies value, the default will be used. true:cancel the interval of LSA originate, the interval is 0. false:do not cancel the interval of LSA originate.
lsaomaxinterval Default:
None
Specifies the max interval of originate LSA . Valid value is an integer, in millisecond, from 1 to 10000, the default value is 5000.
lsaostartinterval Default:
None
Specifies the start interval of originate LSA . Valid value is an integer, in millisecond, from 0 to 1000, the default value is 500.
ospf
required
Default:
None
The ID of the ospf process. Valid values are an integer, 1 - 4294967295, the default value is 1.
route_id Default:
None
Specifies the ospf private route id,. Valid values are a string, formatted as an IP address (i.e. "10.1.1.1") the length is 0 - 20.
spfholdinterval Default:
None
Specifies the hold interval to calculate SPF when use intelligent timer. Valid value is an integer, in millisecond, from 1 to 5000, the default value is 200.
spfinterval Default:
None
Specifies the interval to calculate SPF when use second level timer. Valid value is an integer, in second, from 1 to 10.
spfintervalmi Default:
None
Specifies the interval to calculate SPF when use millisecond level timer. Valid value is an integer, in millisecond, from 1 to 10000.
spfintervaltype
    Choices:
  • intelligent-timer
  • timer
  • millisecond
Specifies the mode of timer which used to calculate SPF. If set the parameter but noe specifies value, the default will be used. If is intelligent-timer, then use intelligent timer. If is timer, then use second level timer. If is millisecond, then use millisecond level timer.
spfmaxinterval Default:
None
Specifies the max interval to calculate SPF when use intelligent timer. Valid value is an integer, in millisecond, from 1 to 20000, the default value is 5000.
spfstartinterval Default:
None
Specifies the start interval to calculate SPF when use intelligent timer. Valid value is an integer, in millisecond, from 1 to 1000, the default value is 50.
state
    Choices:
  • present
  • absent
Specify desired state of the resource.
vrf Default:
_public_
Specifies the vpn instance which use ospf,length is 1 - 31. Valid values are a string.

Examples

- name: ospf vrf module test
  hosts: cloudengine
  connection: local
  gather_facts: no
  vars:
    cli:
      host: "{{ inventory_hostname }}"
      port: "{{ ansible_ssh_port }}"
      username: "{{ username }}"
      password: "{{ password }}"
      transport: cli

  tasks:

  - name: Configure ospf route id
    ce_ospf_vrf:
      ospf: 2
      route_id: 2.2.2.2
      lsaointervalflag: False
      lsaointerval: 2
      provider: "{{ cli }}"

Return Values

Common return values are documented here, the following are the fields unique to this module:

Key Returned Description
changed
boolean
always
check to see if a change was made on the device

end_state
dict
verbose mode
k/v pairs of configuration after module execution

Sample:
{'processId': '2', 'vrfName': '_public_', 'description': None, 'bandwidthReference': '100', 'spfScheduleMaxInterval': '10000', 'lsaArrivalHoldInterval': '500', 'lsaOriginateHoldInterval': '1000', 'lsaOriginateInterval': '2', 'lsaOriginateIntervalFlag': 'false', 'spfScheduleHoldInterval': '1000', 'routerId': '2.2.2.2', 'spfScheduleInterval': None, 'spfScheduleStartInterval': '500', 'spfScheduleIntervalType': 'intelligent-timer', 'lsaOriginateMaxInterval': '5000', 'lsaArrivalStartInterval': '500', 'spfScheduleIntervalMillisecond': None, 'lsaArrivalFlag': 'false', 'lsaOriginateStartInterval': '500', 'lsaArrivalInterval': None, 'lsaArrivalMaxInterval': '1000'}
existing
dict
verbose mode
k/v pairs of existing configuration

Sample:
{'processId': '2', 'vrfName': '_public_', 'description': None, 'bandwidthReference': '100', 'spfScheduleMaxInterval': '10000', 'lsaArrivalHoldInterval': '500', 'lsaOriginateHoldInterval': '1000', 'lsaOriginateInterval': '2', 'lsaOriginateIntervalFlag': 'false', 'spfScheduleHoldInterval': '1000', 'routerId': '2.2.2.2', 'spfScheduleInterval': None, 'spfScheduleStartInterval': '500', 'spfScheduleIntervalType': 'intelligent-timer', 'lsaOriginateMaxInterval': '5000', 'lsaArrivalStartInterval': '500', 'spfScheduleIntervalMillisecond': None, 'lsaArrivalFlag': 'false', 'lsaOriginateStartInterval': '500', 'lsaArrivalInterval': None, 'lsaArrivalMaxInterval': '1000'}
proposed
dict
verbose mode
k/v pairs of parameters passed into module

Sample:
{'description': None, 'lsaoholdinterval': '1000', 'lsaointerval': '2', 'bandwidth': '100', 'process_id': '2', 'vrf': '_public_', 'lsaaholdinterval': '500', 'lsaointervalflag': 'False', 'lsaomaxinterval': '5000', 'lsaalflag': 'False', 'lsaastartinterval': '500', 'lsaamaxinterval': '1000', 'lsaostartinterval': '500', 'spfintervaltype': 'intelligent-timer', 'lsaainterval': None, 'spfstartinterval': '500', 'route_id': '2.2.2.2', 'spfmaxinterval': '10000', 'spfholdinterval': '1000', 'spfinterval': None, 'spfintervalmi': None}
updates
list
always
commands sent to the device

Sample:
['ospf 2']


Status

This module is flagged as preview which means that it is not guaranteed to have a backwards compatible interface.

Author

  • Yang yang (@CloudEngine Ansible)

Hint

If you notice any issues in this documentation you can edit this document to improve it.

© 2012–2018 Michael DeHaan
© 2018–2019 Red Hat, Inc.
Licensed under the GNU General Public License version 3.
https://docs.ansible.com/ansible/2.5/modules/ce_ospf_vrf_module.html