ce_info_center_log – Manages information center log configuration on HUAWEI CloudEngine switches
New in version 2.4.
Synopsis
- Setting the Timestamp Format of Logs. Configuring the Device to Output Logs to the Log Buffer.
Parameters
Parameter | Choices/Defaults | Comments |
---|---|---|
channel_id - | Specifies a channel ID. The value is an integer ranging from 0 to 9. | |
log_buff_enable - |
| Enables the Switch to send logs to the log buffer. |
log_buff_size - | Specifies the maximum number of logs in the log buffer. The value is an integer that ranges from 0 to 10240. If logbuffer-size is 0, logs are not displayed. | |
log_enable - |
| Indicates whether log filtering is enabled. |
log_level - |
| Specifies a log severity. |
log_time_stamp - |
| Sets the timestamp format of logs. |
module_name - | Specifies the name of a module. The value is a module name in registration logs. | |
state - |
| Determines whether the config should be present or not on the device. |
Notes
Note
- This module requires the netconf system service be enabled on the remote device being managed.
- Recommended connection is
netconf
. - This module also works with
local
connections for legacy playbooks.
Examples
- name: CloudEngine info center log test hosts: cloudengine connection: local gather_facts: no vars: cli: host: "{{ inventory_hostname }}" port: "{{ ansible_ssh_port }}" username: "{{ username }}" password: "{{ password }}" transport: cli tasks: - name: "Setting the timestamp format of logs" ce_info_center_log: log_time_stamp: date_tenthsecond provider: "{{ cli }}" - name: "Enabled to output information to the log buffer" ce_info_center_log: log_buff_enable: true provider: "{{ cli }}" - name: "Set the maximum number of logs in the log buffer" ce_info_center_log: log_buff_size: 100 provider: "{{ cli }}" - name: "Set a rule for outputting logs to a channel" ce_info_center_log: module_name: aaa channel_id: 1 log_enable: true log_level: critical provider: "{{ cli }}"
Return Values
Common return values are documented here, the following are the fields unique to this module:
Key | Returned | Description |
---|---|---|
changed boolean | always | check to see if a change was made on the device Sample: True |
end_state dictionary | verbose mode | k/v pairs of configuration after module execution Sample: {'log_time_stamp': 'date_tenthsecond'} |
existing dictionary | verbose mode | k/v pairs of existing configuration Sample: {'log_time_stamp': 'date_second'} |
proposed dictionary | verbose mode | k/v pairs of parameters passed into module Sample: {'log_time_stamp': 'date_tenthsecond', 'state': 'present'} |
updates list | always | commands sent to the device Sample: ['info-center timestamp log date precision-time tenth-second'] |
Status
- This module is not guaranteed to have a backwards compatible interface. [preview]
- This module is maintained by the Ansible Community. [community]
Authors
- QijunPan (@QijunPan)
Hint
If you notice any issues in this documentation you can edit this document to improve it.
© 2012–2018 Michael DeHaan
© 2018–2019 Red Hat, Inc.
Licensed under the GNU General Public License version 3.