bigip_monitor_external – Manages external LTM monitors on a BIG-IP
New in version 2.6.
Synopsis
- Manages external LTM monitors on a BIG-IP.
Parameters
Parameter | Choices/Defaults | Comments | |
---|---|---|---|
arguments string | Specifies any command-line arguments that the script requires. | ||
description string added in 2.7 | The description of the monitor. | ||
external_program string | Specifies the name of the file for the monitor to use. In order to reference a file, you must first import it using options on the System > File Management > External Monitor Program File List > Import screen. The BIG-IP system automatically places the file in the proper location on the file system. | ||
interval integer | The interval specifying how frequently the monitor instance of this template will run. If this parameter is not provided when creating a new monitor, then the default value will be 5. This value must be less than the timeout value. | ||
ip string | IP address part of the IP/port definition. If this parameter is not provided when creating a new monitor, then the default value will be '*'. | ||
name string / required | Specifies the name of the monitor. | ||
parent string | Default: "/Common/external" | The parent template of this monitor template. Once this value has been set, it cannot be changed. By default, this value is the http parent on the Common partition. | |
partition string | Default: "Common" | Device partition to manage resources on. | |
password string / required | The password for the user account used to connect to the BIG-IP. You may omit this option by setting the environment variable F5_PASSWORD .aliases: pass, pwd | ||
port string | Port address part of the IP/port definition. If this parameter is not provided when creating a new monitor, then the default value will be '*'. Note that if specifying an IP address, a value between 1 and 65535 must be specified. | ||
provider dictionary added in 2.5 | A dict object containing connection details. | ||
password string / required | The password for the user account used to connect to the BIG-IP. You may omit this option by setting the environment variable F5_PASSWORD .aliases: pass, pwd | ||
server string / required | The BIG-IP host. You may omit this option by setting the environment variable F5_SERVER . | ||
server_port integer | Default: 443 | The BIG-IP server port. You may omit this option by setting the environment variable F5_SERVER_PORT . | |
ssh_keyfile path | Specifies the SSH keyfile to use to authenticate the connection to the remote device. This argument is only used for cli transports. You may omit this option by setting the environment variable ANSIBLE_NET_SSH_KEYFILE . | ||
timeout integer | Default: 10 | Specifies the timeout in seconds for communicating with the network device for either connecting or sending commands. If the timeout is exceeded before the operation is completed, the module will error. | |
transport string |
| Configures the transport connection to use when connecting to the remote device. | |
user string / required | The username to connect to the BIG-IP with. This user must have administrative privileges on the device. You may omit this option by setting the environment variable F5_USER . | ||
validate_certs boolean |
| If no , SSL certificates are not validated. Use this only on personally controlled sites using self-signed certificates.You may omit this option by setting the environment variable F5_VALIDATE_CERTS . | |
server string / required | The BIG-IP host. You may omit this option by setting the environment variable F5_SERVER . | ||
server_port integer added in 2.2 | Default: 443 | The BIG-IP server port. You may omit this option by setting the environment variable F5_SERVER_PORT . | |
state string |
| When present , ensures that the monitor exists.When absent , ensures the monitor is removed. | |
timeout integer | The number of seconds in which the node or service must respond to the monitor request. If the target responds within the set time period, it is considered up. If the target does not respond within the set time period, it is considered down. You can change this number to any number you want, however, it should be 3 times the interval number of seconds plus 1 second. If this parameter is not provided when creating a new monitor, then the default value will be 16 . | ||
user string / required | The username to connect to the BIG-IP with. This user must have administrative privileges on the device. You may omit this option by setting the environment variable F5_USER . | ||
validate_certs boolean added in 2.0 |
| If no , SSL certificates are not validated. Use this only on personally controlled sites using self-signed certificates.You may omit this option by setting the environment variable F5_VALIDATE_CERTS . | |
variables dictionary | Specifies any variables that the script requires. Note that double quotes in values will be suppressed. |
Notes
Note
- For more information on using Ansible to manage F5 Networks devices see https://www.ansible.com/integrations/networks/f5.
- Requires BIG-IP software version >= 12.
- The F5 modules only manipulate the running configuration of the F5 product. To ensure that BIG-IP specific configuration persists to disk, be sure to include at least one task that uses the bigip_config module to save the running configuration. Refer to the module’s documentation for the correct usage of the module to save your running configuration.
Examples
- name: Create an external monitor bigip_monitor_external: name: foo state: present provider: user: admin password: secret server: lb.mydomain.com delegate_to: localhost - name: Create an external monitor with variables bigip_monitor_external: name: foo timeout: 10 variables: var1: foo var2: bar state: present provider: user: admin password: secret server: lb.mydomain.com delegate_to: localhost - name: Add a variable to an existing set bigip_monitor_external: name: foo timeout: 10 variables: var1: foo var2: bar cat: dog state: present provider: user: admin password: secret server: lb.mydomain.com delegate_to: localhost
Return Values
Common return values are documented here, the following are the fields unique to this module:
Key | Returned | Description |
---|---|---|
description string | changed | The description of the monitor. Sample: Important Monitor |
interval integer | changed | The new interval in which to run the monitor check. Sample: 2 |
ip string | changed | The new IP of IP/port definition. Sample: 10.12.13.14 |
parent string | changed | New parent template of the monitor. Sample: external |
timeout integer | changed | The new timeout in which the remote system must respond to the monitor. Sample: 10 |
Status
- This module is not guaranteed to have a backwards compatible interface. [preview]
- This module is maintained by an Ansible Partner. [certified]
Authors
- Tim Rupp (@caphrim007)
- Wojciech Wypior (@wojtek0806)
Hint
If you notice any issues in this documentation you can edit this document to improve it.
© 2012–2018 Michael DeHaan
© 2018–2019 Red Hat, Inc.
Licensed under the GNU General Public License version 3.
https://docs.ansible.com/ansible/2.8/modules/bigip_monitor_external_module.html