bigip_monitor_external – Manages external LTM monitors on a BIG-IP

New in version 2.6.

Synopsis

  • Manages external LTM monitors on a BIG-IP.

Parameters

Parameter Choices/Defaults Comments
arguments
string
Specifies any command-line arguments that the script requires.
description
string
added in 2.7
The description of the monitor.
external_program
string
Specifies the name of the file for the monitor to use. In order to reference a file, you must first import it using options on the System > File Management > External Monitor Program File List > Import screen. The BIG-IP system automatically places the file in the proper location on the file system.
interval
integer
The interval specifying how frequently the monitor instance of this template will run. If this parameter is not provided when creating a new monitor, then the default value will be 5. This value must be less than the timeout value.
ip
string
IP address part of the IP/port definition. If this parameter is not provided when creating a new monitor, then the default value will be '*'.
name
string / required
Specifies the name of the monitor.
parent
string
Default:
"/Common/external"
The parent template of this monitor template. Once this value has been set, it cannot be changed. By default, this value is the http parent on the Common partition.
partition
string
Default:
"Common"
Device partition to manage resources on.
password
string / required
The password for the user account used to connect to the BIG-IP.
You may omit this option by setting the environment variable F5_PASSWORD.

aliases: pass, pwd
port
string
Port address part of the IP/port definition. If this parameter is not provided when creating a new monitor, then the default value will be '*'. Note that if specifying an IP address, a value between 1 and 65535 must be specified.
provider
dictionary
added in 2.5
A dict object containing connection details.
password
string / required
The password for the user account used to connect to the BIG-IP.
You may omit this option by setting the environment variable F5_PASSWORD.

aliases: pass, pwd
server
string / required
The BIG-IP host.
You may omit this option by setting the environment variable F5_SERVER.
server_port
integer
Default:
443
The BIG-IP server port.
You may omit this option by setting the environment variable F5_SERVER_PORT.
ssh_keyfile
path
Specifies the SSH keyfile to use to authenticate the connection to the remote device. This argument is only used for cli transports.
You may omit this option by setting the environment variable ANSIBLE_NET_SSH_KEYFILE.
timeout
integer
Default:
10
Specifies the timeout in seconds for communicating with the network device for either connecting or sending commands. If the timeout is exceeded before the operation is completed, the module will error.
transport
string
    Choices:
  • cli
  • rest
Configures the transport connection to use when connecting to the remote device.
user
string / required
The username to connect to the BIG-IP with. This user must have administrative privileges on the device.
You may omit this option by setting the environment variable F5_USER.
validate_certs
boolean
    Choices:
  • no
  • yes
If no, SSL certificates are not validated. Use this only on personally controlled sites using self-signed certificates.
You may omit this option by setting the environment variable F5_VALIDATE_CERTS.
server
string / required
The BIG-IP host.
You may omit this option by setting the environment variable F5_SERVER.
server_port
integer
added in 2.2
Default:
443
The BIG-IP server port.
You may omit this option by setting the environment variable F5_SERVER_PORT.
state
string
    Choices:
  • present
  • absent
When present, ensures that the monitor exists.
When absent, ensures the monitor is removed.
timeout
integer
The number of seconds in which the node or service must respond to the monitor request.
If the target responds within the set time period, it is considered up.
If the target does not respond within the set time period, it is considered down.
You can change this number to any number you want, however, it should be 3 times the interval number of seconds plus 1 second.
If this parameter is not provided when creating a new monitor, then the default value will be 16.
user
string / required
The username to connect to the BIG-IP with. This user must have administrative privileges on the device.
You may omit this option by setting the environment variable F5_USER.
validate_certs
boolean
added in 2.0
    Choices:
  • no
  • yes
If no, SSL certificates are not validated. Use this only on personally controlled sites using self-signed certificates.
You may omit this option by setting the environment variable F5_VALIDATE_CERTS.
variables
dictionary
Specifies any variables that the script requires.
Note that double quotes in values will be suppressed.

Notes

Note

  • For more information on using Ansible to manage F5 Networks devices see https://www.ansible.com/integrations/networks/f5.
  • Requires BIG-IP software version >= 12.
  • The F5 modules only manipulate the running configuration of the F5 product. To ensure that BIG-IP specific configuration persists to disk, be sure to include at least one task that uses the bigip_config module to save the running configuration. Refer to the module’s documentation for the correct usage of the module to save your running configuration.

Examples

- name: Create an external monitor
  bigip_monitor_external:
    name: foo
    state: present
    provider:
      user: admin
      password: secret
      server: lb.mydomain.com
  delegate_to: localhost

- name: Create an external monitor with variables
  bigip_monitor_external:
    name: foo
    timeout: 10
    variables:
      var1: foo
      var2: bar
    state: present
    provider:
      user: admin
      password: secret
      server: lb.mydomain.com
  delegate_to: localhost

- name: Add a variable to an existing set
  bigip_monitor_external:
    name: foo
    timeout: 10
    variables:
      var1: foo
      var2: bar
      cat: dog
    state: present
    provider:
      user: admin
      password: secret
      server: lb.mydomain.com
  delegate_to: localhost

Return Values

Common return values are documented here, the following are the fields unique to this module:

Key Returned Description
description
string
changed
The description of the monitor.

Sample:
Important Monitor
interval
integer
changed
The new interval in which to run the monitor check.

Sample:
2
ip
string
changed
The new IP of IP/port definition.

Sample:
10.12.13.14
parent
string
changed
New parent template of the monitor.

Sample:
external
timeout
integer
changed
The new timeout in which the remote system must respond to the monitor.

Sample:
10


Status

Authors

  • Tim Rupp (@caphrim007)
  • Wojciech Wypior (@wojtek0806)

Hint

If you notice any issues in this documentation you can edit this document to improve it.

© 2012–2018 Michael DeHaan
© 2018–2019 Red Hat, Inc.
Licensed under the GNU General Public License version 3.
https://docs.ansible.com/ansible/2.8/modules/bigip_monitor_external_module.html