Synopsis
- Manages F5 BIG-IP LTM HTTP monitors.
Parameters
Parameter | Choices/Defaults | Comments | |
---|---|---|---|
description string | The description of the monitor. | ||
interval integer | The interval specifying how frequently the monitor instance of this template will run. If this parameter is not provided when creating a new monitor, the default value is 5. This value must be less than the timeout value. | ||
ip string | IP address part of the IP/port definition. If this parameter is not provided when creating a new monitor, the default value is '*'. | ||
name string / required | Monitor name. | ||
parent string | Default: "/Common/http" | The parent template of this monitor template. Once this value has been set, it cannot be changed. By default, this value is the http parent on the Common partition. | |
partition string | Default: "Common" | Device partition to manage resources on. | |
port string | Port address part of the IP/port definition. If this parameter is not provided when creating a new monitor, the default value is '*'. If specifying an IP address, you must specify a value between 1 and 65535. | ||
provider dictionary added in 1.0.0 of f5networks.f5_modules | A dict object containing connection details. | ||
auth_provider string | Configures the auth provider for to obtain authentication tokens from the remote device. This option is really used when working with BIG-IQ devices. | ||
no_f5_teem boolean |
| If yes , TEEM telemetry data is not sent to F5.You may omit this option by setting the environment variable F5_TELEMETRY_OFF .Previously used variable F5_TEEM is deprecated as its name was confusing. | |
password string / required | The password for the user account used to connect to the BIG-IP. You may omit this option by setting the environment variable F5_PASSWORD .aliases: pass, pwd | ||
server string / required | The BIG-IP host. You may omit this option by setting the environment variable F5_SERVER . | ||
server_port integer | Default: 443 | The BIG-IP server port. You may omit this option by setting the environment variable F5_SERVER_PORT . | |
timeout integer | Specifies the timeout in seconds for communicating with the network device for either connecting or sending commands. If the timeout is exceeded before the operation is completed, the module will error. | ||
transport string |
| Configures the transport connection to use when connecting to the remote device. | |
user string / required | The username to connect to the BIG-IP with. This user must have administrative privileges on the device. You may omit this option by setting the environment variable F5_USER . | ||
validate_certs boolean |
| If no , SSL certificates are not validated. Use this only on personally controlled sites using self-signed certificates.You may omit this option by setting the environment variable F5_VALIDATE_CERTS . | |
receive string | The Receive string for the monitor call. | ||
receive_disable string | This setting works like receive , except the system marks the node or pool member disabled when its response matches the receive_disable string but not receive . To use this setting, you must specify both receive_disable and receive . | ||
reverse boolean |
| Specifies whether the monitor operates in reverse mode. When the monitor is in reverse mode, a successful receive string match marks the monitored object down instead of up. You can use the this mode only if you configure the receive option.This parameter is not compatible with the time_until_up parameter. If time_until_up is specified, it must be 0 . Or, if it already exists, it must be 0 . | |
send string | The Send string for the monitor call. When creating a new monitor, if this value is not provided, the default GET /\r\n is used. | ||
state string |
| When present , ensures the monitor exists.When absent , ensures the monitor is removed. | |
target_password string | Specifies the password, if the monitored target requires authentication. | ||
target_username string | Specifies the user name, if the monitored target requires authentication. | ||
time_until_up integer | Specifies the amount of time in seconds after the first successful response before a node is marked up. A value of 0 causes a node to be marked up immediately after a valid response is received from the node. If this parameter is not provided when creating a new monitor, the default value will be 0. | ||
timeout integer | The number of seconds in which the node or service must respond to the monitor request. If the target responds within the set time period, it is considered up. If the target does not respond within the set time period, it is considered down. You can change this to any number, however, it should be 3 times the interval number of seconds plus 1 second. If this parameter is not provided when creating a new monitor, the default value is 16. |
Notes
Note
- Requires BIG-IP software version >= 12
- For more information on using Ansible to manage F5 Networks devices see https://www.ansible.com/integrations/networks/f5.
- Requires BIG-IP software version >= 12.
- The F5 modules only manipulate the running configuration of the F5 product. To ensure that BIG-IP specific configuration persists to disk, be sure to include at least one task that uses the f5networks.f5_modules.bigip_config module to save the running configuration. Refer to the module’s documentation for the correct usage of the module to save your running configuration.
Examples
- name: Create HTTP Monitor bigip_monitor_http: state: present ip: 10.10.10.10 name: my_http_monitor provider: server: lb.mydomain.com user: admin password: secret delegate_to: localhost - name: Remove HTTP Monitor bigip_monitor_http: state: absent name: my_http_monitor provider: server: lb.mydomain.com user: admin password: secret delegate_to: localhost - name: Include a username and password in the HTTP monitor bigip_monitor_http: state: absent name: my_http_monitor target_username: monitor_user target_password: monitor_pass provider: server: lb.mydomain.com user: admin password: secret delegate_to: localhost
Return Values
Common return values are documented here, the following are the fields unique to this module:
Key | Returned | Description |
---|---|---|
description string | changed | The description of the monitor. Sample: Important_Monitor |
interval integer | changed | The new interval at which to run the monitor check. Sample: 2 |
ip string | changed | The new IP of IP/port definition. Sample: 10.12.13.14 |
parent string | changed | New parent template of the monitor. Sample: http |
reverse boolean | changed | Whether the monitor operates in reverse mode. Sample: True |
time_until_up integer | changed | The new time in which to mark a system as up after first successful response. Sample: 2 |
timeout integer | changed | The new timeout in which the remote system must respond to the monitor. Sample: 10 |