ce_vxlan_vap - Manages VXLAN virtual access point on HUAWEI CloudEngine Devices.

New in version 2.4.

Synopsis

  • Manages VXLAN Virtual access point on HUAWEI CloudEngine Devices.

Options

parameter required default choices comments
bind_vlan_id
no
Specifies the VLAN binding to a BD(Bridge Domain). The value is an integer ranging ranging from 1 to 4094.
bridge_domain_id
no
Specifies a bridge domain ID. The value is an integer ranging from 1 to 16777215.
ce_vid
no
When encapsulation is 'dot1q', specifies a VLAN ID in the outer VLAN tag. When encapsulation is 'qinq', specifies an outer VLAN ID for double-tagged packets to be received by a Layer 2 sub-interface. The value is an integer ranging from 1 to 4094.
encapsulation
no
  • dot1q
  • default
  • untag
  • qinq
  • none
Specifies an encapsulation type of packets allowed to pass through a Layer 2 sub-interface.
l2_sub_interface
no
Specifies an Sub-Interface full name, i.e. "10GE1/0/41.1". The value is a string of 1 to 63 case-insensitive characters, spaces supported.
pe_vid
no
When encapsulation is 'qinq', specifies an inner VLAN ID for double-tagged packets to be received by a Layer 2 sub-interface. The value is an integer ranging from 1 to 4094.
state
no present
  • present
  • absent
Determines whether the config should be present or not on the device.

Examples

- name: vxlan vap module test
  hosts: ce128
  connection: local
  gather_facts: no
  vars:
    cli:
      host: "{{ inventory_hostname }}"
      port: "{{ ansible_ssh_port }}"
      username: "{{ username }}"
      password: "{{ password }}"
      transport: cli

  tasks:

  - name: Create a papping between a VLAN and a BD
    ce_vxlan_vap:
      bridge_domain_id: 100
      bind_vlan_id: 99
      provider: "{{ cli }}"

  - name: Bind a Layer 2 sub-interface to a BD
    ce_vxlan_vap:
      bridge_domain_id: 100
      l2_sub_interface: 10GE2/0/20.1
      provider: "{{ cli }}"

  - name: Configure an encapsulation type on a Layer 2 sub-interface
    ce_vxlan_vap:
      l2_sub_interface: 10GE2/0/20.1
      encapsulation: dot1q
      provider: "{{ cli }}"

Return Values

Common return values are documented here Return Values, the following are the fields unique to this module:

name description returned type sample
changed
check to see if a change was made on the device
always boolean True
end_state
k/v pairs of configuration after module execution
verbose mode dict {'bind_intf_list': ['110GE2/0/20.1', '10GE2/0/20.2'], 'bind_vlan_list': ['99'], 'bridge_domain_id': '100'}
existing
k/v pairs of existing configuration
verbose mode dict {'bind_intf_list': ['10GE2/0/20.1', '10GE2/0/20.2'], 'bind_vlan_list': [], 'bridge_domain_id': '100'}
proposed
k/v pairs of parameters passed into module
verbose mode dict {'state="present"': None, 'bind_vlan_id': '99', 'bridge_domain_id': '100'}
updates
commands sent to the device
always list ['bridge-domain 100', 'l2 binding vlan 99']

Status

This module is flagged as preview which means that it is not guaranteed to have a backwards compatible interface.

For help in developing on modules, should you be so inclined, please read Community Information & Contributing, Testing Ansible and Developing Modules.

© 2012–2018 Michael DeHaan
© 2018–2019 Red Hat, Inc.
Licensed under the GNU General Public License version 3.
https://docs.ansible.com/ansible/2.4/ce_vxlan_vap_module.html