| Parameter | Choices/Defaults | Comments |
|---|---|---|
| baud integer |
| This is the baud rate to assign to the port. 0=300, 1=1200, 2=2400, 3=4800, 4=9600, 5=19200, 6=38400, 7=57600, 8=115200, 9=230400, 10=460800 |
| break_allow boolean |
| This is if the break character is allowed to be passed through the port, 0=Off, 1=On |
| cmd integer |
| This is the Admin Mode to assign to the port, 0=Deny, 1=Permit. |
| cpm_password string / required | This is the Password of the WTI device to send the module. | |
| cpm_url string / required | This is the URL of the WTI device to send the module. | |
| cpm_username string / required | This is the Username of the WTI device to send the module. | |
| echo boolean |
| -This is the command echo parameter to assign to the port, 0=Off, 1=On |
| handshake integer |
| This is the handshake to assign to the port, 0=None, 1=XON/XOFF, 2=RTS/CTS, 3=Both. |
| logoff string | This is the logout character to assign to the port If preceded by a ^ character, the sequence will be a control character. Used if seq is set to 0 or 1 | |
| mode integer |
| This is the port mode to assign to the port, 0=Any-to-Any. 1=Passive, 2=Buffer, 3=Modem, 4=ModemPPP. |
| parity integer |
| This is the parity to assign to the port, 0=7-None, 1=7-Even, 2=7-Odd, 3=8-None, 4=8-Even, 5=8-Odd. |
| port integer / required | This is the port number that is getting the action performed on. | |
| portname string | This is the Name of the Port that is displayed. | |
| seq integer |
| This is the type of Sequence Disconnect to assign to the port, 0=Three Characters (before and after), 1=One Character Only, 2=Off |
| stopbits integer |
| This is the stop bits to assign to the port, 0=1 Stop Bit, 1=2 Stop Bit. |
| tout integer |
| This is the Port Activity Timeout to assign to the port, 0=Off, 1=5 Min, 2=15 Min, 3=30 Min, 4=90 Min, 5=1 Min. |
| use_https boolean |
| Designates to use an https connection or http connection. |
| use_proxy boolean |
| Flag to control if the lookup will observe HTTP proxy environment variables when present. |
| validate_certs boolean |
| If false, SSL certificates will not be validated. This should only be used on personally controlled sites using self-signed certificates. |
Notes
Note
- Use
groups/cpminmodule_defaultsto set common options used between CPM modules.
Examples
# Set Serial Port Parameters
- name: Set the Port Parameters for port 2 of a WTI device
cpm_serial_port_config:
cpm_url: "nonexist.wti.com"
cpm_username: "super"
cpm_password: "super"
use_https: true
validate_certs: false
port: "2"
portname: "RouterLabel"
baud: "7"
handshake: "1"
stopbits: "0"
parity: "0"
mode: "0"
cmd: "0"
seq: "1"
tout: "1"
echo: "0"
break_allow: "0"
logoff: "^H"
# Set Serial Port Port Name and Baud Rate Parameters
- name: Set New port name and baud rate (115k) for port 4 of a WTI device
cpm_serial_port_config:
cpm_url: "nonexist.wti.com"
cpm_username: "super"
cpm_password: "super"
use_https: true
validate_certs: false
port: "4"
portname: "NewPortName1"
baud: "8"
Return Values
Common return values are documented here, the following are the fields unique to this module:
| Key | Returned | Description |
|---|---|---|
| data string | always | The output JSON returned from the commands sent |
Authors
- Western Telematic Inc. (@wtinetworkgear)
© 2012–2018 Michael DeHaan
© 2018–2019 Red Hat, Inc.
Licensed under the GNU General Public License version 3.
https://docs.ansible.com/ansible/2.10/collections/wti/remote/cpm_serial_port_config_module.html