Module_Interface
Module
Module_Interface
Module summary
Orber generated stubs/skeletons.
Description
This module contains the stub/skeleton functions generated by IC.
Starting a Orber server can be done in three ways:
- Normal - when the server dies Orber forgets all knowledge of the server.
- Supervisor child - adding the configuration parameter
{sup_child, true}
theoe_create_link/2
function returns{ok, Pid, ObjRef}
which can be handled by the application supervisor/stdlib-1.7 or later. - Persistent object reference - adding the configuration parameters
{persistent, true}
and{regname, {global, term()}}
Orber will remember the object reference until the server terminates with reason normal or shutdown. Hence, if the server is started as a transient supervisor child we do not receive a 'OBJECT_NOT_EXIST' exception when it has crashed and is being restarted.
The Orber stub can be used to start a pseudo object
, which will create a non-server implementation. A pseudo object introduce some limitations:
- The functions
oe_create_link/2
is equal tooe_create/2
, i.e., no link can or will be created. - The
BIF:s self()
andprocess_flag(trap_exit,true)
behaves incorrectly. - The
IC
option{{impl, "M::I"}, "other_impl"}
has no effect. The call-back functions must be implemented in a file calledM_I_impl.erl
- The
IC
optionfrom
has no effect. - The call-back functions must be implemented as if the
IC
option{this, "M::I"}
was used. - Server
State
changes have no effect. The user can provide information via theEnv
start parameter and the State returned frominit/2
will be the State passed in following invocations. - If a call-back function replies with the
Timeout
parameter set it have no effect. - Operations defined as
oneway
are blocking until the operation replies. - The option
{pseudo, true}
overrides all other start options. - Only the functions, besides own definitions,
init/2
(called via oe_create*/2) andterminate/2
(called via corba:dispose/1) must be implemented.
By adopting the rules for pseudo
objects described above we can use oe_create/2
to create server
or pseudo
objects, by excluding or including the option {pseudo, true}
, without changing the call-back module.
If you start a object without {regname, RegName}
it can only be accessed through the returned object key. Started with a {regname, RegName}
the name is registered locally or globally.
To avoid flooding Orber with old object references start erlang using the flag -orber objectkeys_gc_time Time, which will remove all object references related to servers being dead for Time seconds. To avoid extra overhead, i.e., performing garbage collect if no persistent objects are started, the objectkeys_gc_time default value is infinity. For more information, see the orber and corba documentation.
Exports
Module_Interface:typeID() -> TypeId
Types:
TypeId = string(), e.g., "IDL:Module/Interface:1.0"
Returns the Type ID related to this stub/skeleton
Module_Interface:oe_create() -> ObjRef
Types:
ObjRef = #object reference
Start a Orber server.
Module_Interface:oe_create_link() -> ObjRef
Types:
ObjRef = #object reference
Start a linked Orber server.
Module_Interface:oe_create(Env) -> ObjRef
Types:
Env = term() ObjRef = #object reference
Start a Orber server passing Env to init/1
.
Module_Interface:oe_create_link(Env) -> ObjRef
Types:
Env = term() ObjRef = #object reference
Start a linked Orber server passing Env to init/1
.
Module_Interface:oe_create(Env, Options) -> ObjRef
Types:
Env = term() ObjRef = #object reference Options = [{sup_child, false} | {persistent, Bool} | {regname, RegName} | {pseudo, Bool} | {local_typecheck, Bool} | {survive_exit, Bool} | {create_options, [CreateOpts]}] Bool = true | false RegName = {global, term()} | {local, atom()} CreateOpts = {debug, [Dbg]} | {timeout, Time} Dbg = trace | log | statistics | {log_to_file, FileName}
Start a Orber server passing Env to init/1
.
If the option {pseudo, true}
is used, all other options are overridden. As default, this option is set to false.
This function cannot be used for starting a server as supervisor child. If started as persistent
, the options [{persistent, true}, {regname, {global, term()}}]
must be used and Orber will only forget the object reference if it terminates with reason normal or shutdown.
The option {local_typecheck, boolean()}
, which overrides the Local Typechecking
environment flag, turns on or off typechecking. If activated, parameters, replies and raised exceptions will be checked to ensure that the data is correct, when invoking operations on CORBA Objects within the same Orber domain. Due to the extra overhead, this option MAY ONLY be used during testing and development.
{survive_exit, boolean()}
overrides the EXIT Tolerance
environment flag. If activated, the server will not terminate, even though the call-back module returns EXIT.
Time
specifies how long time, in milliseconds, the server is allowed to spend initializing. For more information about the Dbg
options, see the sys
module.
Module_Interface:oe_create_link(Env, Options) -> Return
Types:
Env = term() Return = ObjRef | {ok, Pid, ObjRef} ObjRef = #object reference Options = [{sup_child, Bool} | {persistent, Bool} | {regname, RegName} | {pseudo, Bool} | {local_typecheck, Bool} | {survive_exit, Bool} | {create_options, [CreateOpts]}] Bool = true | false RegName = {global, term()} | {local, atom()} CreateOpts = {debug, [Dbg]} | {timeout, Time} Dbg = trace | log | statistics | {log_to_file, FileName}
Start a linked Orber server passing Env to init/1
.
If the option {pseudo, true}
is used, all other options are overridden and no link will be created. As default, this option is set to false.
This function can be used for starting a server as persistent or supervisor child. At the moment [{persistent, true}, {regname, {global, term()}}]
must be used to start a server as persistent, i.e., if a server died and is in the process of being restarted a call to the server will not raise 'OBJECT_NOT_EXIST'
exception. Orber will only forget the object reference if it terminates with reason normal or shutdown, hence, the server must be started as transient (for more information see the supervisor documentation).
The options {local_typecheck, boolean()}
and {survive_exit, boolean()}
behaves in the same way as for oe_create/2
.
Time
specifies how long time, in milliseconds, the server is allowed to spend initializing. For more information about the Dbg
options, see the sys
module.
Module_Interface:own_functions(ObjRef, Arg1, ..., ArgN) -> Reply
Module_Interface:own_functions(ObjRef, Options, Arg1, ..., ArgN) -> Reply
Types:
ObjRef = #object reference Options = [Option] | Timeout Option = {timeout, Timeout} | {context, [Context]} Timeout = infinity | integer(milliseconds) Context = #'IOP_ServiceContext'{context_id = CtxId, context_data = CtxData} CtxId = ?ORBER_GENERIC_CTX_ID CtxData = {interface, Interface} | {userspecific, term()} | {configuration, Options} Interface = string() Options = [{Key, Value}] Key = ssl_client_verify | ssl_client_depth | ssl_client_certfile | ssl_client_cacertfile | ssl_client_password | ssl_client_keyfile | ssl_client_ciphers | ssl_client_cachetimeout Value = allowed value associated with the given key ArgX = specified in the IDL-code. Reply = specified in the IDL-code.
The default value for the Timeout
option is infinity
. IPv4 or IPv6 addresses are accepted as local Interface.
The configuration context is used to override the global SSL client side configuration
.
To gain access to #'IOP_ServiceContext'{}
record and the ?ORBER_GENERIC_CTX_ID
macro, you must add -include_lib("orber/include/corba.hrl").
to your module.
Callback functions
The following functions should be exported from a CORBA
callback module. Note, a complete template of the call-back module can be generated automatically by compiling the IDL-file with the IC option {be,erl_template}
. One should also add the same compile options, for example this
or from
, used when generating the stub/skeleton modules.
Exports
Module_Interface_impl:init(Env) -> CallReply
Types:
Env = term() CallReply = {ok, State} | {ok, State, Timeout} | ignore | {stop, StopReason} State = term() Timeout = int() >= 0 | infinity StopReason = term()
Whenever a new server is started, init/1 is the first function called in the specified call-back module.
Module_Interface_impl:terminate(Reason, State) -> ok
Types:
Reason = term() State = term()
This call-back function is called whenever the server is about to terminate.
Module_Interface_impl:code_change(OldVsn, State, Extra) -> CallReply
Types:
OldVsn = undefined | term() State = term() Extra = term() CallReply = {ok, NewState} NewState = term()
Update the internal State
.
Module_Interface_impl:handle_info(Info, State) -> CallReply
Types:
Info = term() State = term() CallReply = {noreply, State} | {noreply, State, Timeout} | {stop, StopReason, State} Timeout = int() >= 0 | infinity StopReason = normal | shutdown | term()
If the configuration parameter {{handle_info, "Module::Interface"}, true} is passed to IC and process_flag(trap_exit,true) is set in the init() call-back this function must be exported.
To be able to handle the Timeout
option in CallReply
in the call-back module the configuration parameter {{handle_info, "Module::Interface"}, true} must be passed to IC.
Module_Interface_impl:own_functions(State, Arg1, ..., ArgN) -> CallReply
Module_Interface_impl:own_functions(This, State, Arg1, ..., ArgN) -> CallReply
Module_Interface_impl:own_functions(This, From, State, Arg1, ..., ArgN) -> ExtCallReply
Module_Interface_impl:own_functions(From, State, Arg1, ..., ArgN) -> ExtCallReply
Types:
This = the servers #object reference State = term() ArgX = specified in the IDL-code. CallReply = {reply, Reply, State} | {reply, Reply, State, Timeout} | {stop, StopReason, Reply, State} | {stop, StopReason, State} | corba:raise(Exception) ExtCallReply = CallReply | corba:reply(From, Reply), {noreply, State} | corba:reply(From, Reply), {noreply, State, Timeout} Reply = specified in the IDL-code. Timeout = int() >= 0 | infinity StopReason = normal | shutdown | term()
All two-way functions must return one of the listed replies or raise any of the exceptions listed in the IDL code (i.e. raises(...)). If the IC compile options this and/or from are used, the implementation must accept the This and/or From parameters.
Module_Interface_impl:own_functions(State, Arg1, ..., ArgN) -> CastReply
Module_Interface_impl:own_functions(This, State, Arg1, ..., ArgN) -> CastReply
Types:
This = the servers #object reference State = term() CastReply = {noreply, State} | {noreply, State, Timeout} | {stop, StopReason, State} ArgX = specified in the IDL-code. Reply = specified in the IDL-code. Timeout = int() >= 0 | infinity StopReason = normal | shutdown | term()
All one-way functions must return one of the listed replies. If the IC compile option this is used, the implementation must accept the This parameter.
© 2010–2017 Ericsson AB
Licensed under the Apache License, Version 2.0.